Menu
Cart 0

12V 80A Rechargeable Sealed Lead Acid Battery

12V 80A Rechargeable Sealed Lead Acid Battery 80AH

12V 80A Rechargeable Sealed Lead Acid Battery

  • Regular price $200.00 USD Sale price$164.99 USD
Best Price Guarantee. [1, 2, 3]
  • Product Url
  • This field is required. Please enter a value.

  • This field is required. Please enter a value.

  • This field is required. Please enter a value.

  • This field is required. Please enter a value.

  • *These fields required. [2] May exclude very large size items because we offer free shipping so our actual cost may be too high due to the size/ weight of item to be able to match the price. [3] Request must be made before order placement. Not valid after order placed. Other restrictions may apply. Please contact us for details.

Buy Now, Pay Later with No Interest if paid in full within 6-12 months. Choose Klarna payment option at the checkout for details of this, and other long-term low-interest financing options.

Free Lifetime Support. SKU / Model: NPD1280AHAFC

Best Price Guarantee [1 2 3]

Call for FREE consultation:

1(855)846-2654

Need installation quote, or help with designing a custom solution? Submit a request for quote.

  • Description
  • Reviews
  • Questions & Answers
  • Make An Offer
  • Warning

Description

Product Description

12V 80A Rechargeable Sealed Lead Acid Battery for Cel-Fi QUATRA RED DAS (Distributed Antenna System) Battery Backup Unit as well as other brand name Public Safety DAS or signal booster, amplifier, enhancing systems requiring extended power supply applications for emergency operational uses.

Specifications:

Nominal Voltage 12V.
Rated capacity (20 hour rate) 80Ah.
Dimensions (inches) 10.24 (length) x 6.61 (width) x 8.31 (height). Total height with terminals = 8.46 inches.
Weight (pounds) 55.8 lbs.

 

Characteristics:

Capacity at 25 Degrees Centigrade 20 Hr. (10.8V) = 80Ah, 3 Hr. (10.8V) = 61.5Ah, 1 Hr. (10.5V) = 46Ah.
Terminal type T14.
Internal resistance (Fully charged at 25 Degrees Centigrade) Approx. 5m Ohm.
Capacity affected by temperature 40°C = 102%, 25°C = 100%, 0°C = 85%, -15°C = 65%.
Self-discharge at 25°C 3 Months Remaining Capacity = 91%, 6 Months Remaining Capacity = 82%, 12 Months Remaining Capacity = 65%.
Nominal operating temperature 25°C ± 3°C (77°F ± 5°F).
Operating temperature range Discharge = -15°C ~ 50°C (5°F ~ 122°F), Charge = -10°C ~ 50°C (14°F ~ 122°F), Storage = -20°C ~ 50°C (-4°F ~ 122°F).
Float charging voltage at 25°C 13.50 to 13.80V Temperature compensation: -18mV/°C.
Cyclic charging voltage at 25°C 14.50 to 15.00V Temperature compensation: -30mV/°C.
Maximum charging current 24A
Maximum discharge current 700A (5 sec.)
Designed floating life at 20°C 10 years

 

Construction:

Component Raw material
Positive plate Lead dioxide
Negative plate Lead
Container ABS
Cover ABS
Separator AGM
Electrolyte Sulfuric acid
Safety valve Rubber
Terminal Copper

 

Battery discharge characteristics at 25 degrees centigrade:

Battery discharge characteristics at 25 degrees centigrade


Battery charging characteristics at 25 degrees centigrade:

Battery charging characteristics at 25 degrees centigrade


Temperature effects on battery capacity:

Temperature effects on battery capacity


Battery self-discharge characteristics:

Battery self-discharge characteristics


Floating battery Life based on temperature:

Floating battery Life based on temperature


Battery cycle life on D.O.D. (depth of discharge) at 25 Deg. C.:

Battery cycle life on D.O.D. (depth of discharge)


OCV (Open Current Voltage) versus battery capacity at 25 Deg. C.:

OCV (Open Current Voltage) versus battery capacity


Battery charging voltage versus temperature graph:

Battery charging voltage versus temperature graph

Reviews

Customer Reviews

Questions & Answers

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question

Data Sheet / User Guide

Make An Offer

  • This field is required. Please enter a value.

  • This field is required. Please enter a value.

  • This field is required. Please enter a value.

  • This field is required. Please enter a value.

  • Input Correct Captcha

Warning

Note: For any signal booster to help, outside signal strength must be at least -110 dB or there must be a clear line of sight to a cell tower that is within twenty miles. Before ordering, please check outside signal level in decibels or ensure that you can make and hold a phone call at any good spot outside where you can mount an exterior antenna. Square footage stated in signal booster listings is based on good signal outside. If it is any weaker, the boosted sq. ft. area will be considerably lower, accordingly.

Kevin K. of Anderson, California gave the following review:

Website is easy to use with plain straight forward info but could have had more on testing signal strength to make sure you get a strong enough booster.

Therefore, please note that stated sq. ft. coverage is based on good signal outside. For best results: If outside signal is weak, we suggest choosing the next higher sq. ft. coverage kit. If outside signal is very weak, we suggest choosing the kit with even more higher sq. ft. range bracket. Basically, higher the sq. ft. bracket, the more powerful the signal amplifier with greater Gain as well as higher uplink and downlink output power.

If outside signal is too weak (weaker than -110 dB), submit request for cell coverage solution assessment. Upon receipt of questionnaire, we will perform residential or business site survey. This will help us determine the system that is needed to improve cell coverage. Then, we will create system design using that system such as femtocell, active or hybrid distributed antenna system (DAS), or other carrier feed signal enhancing method available that will work at your signal-challenged location. Finally, we will schedule for installation after equipment and installation service quote has been approved by you, or your company.

For non installation-included kits: Most home / office / building cell signal booster kits only include bracket to mount exterior antenna on outside wall, edge of roof, or existing pipe up to 2 inches in diameter. Mounting pole not included with most kits, unless stated specifically that it is included for free. Therefore, a mounting post must be purchased separately if you will require it to mount exterior antenna.


Related Products
12V 80A Rechargeable Sealed Lead Acid Battery