Product Description
Featuring a plenum fire rating, this 500 feet CommScope cable spool of aluminum coaxial has a 1/2 inch thickness. With a 6.0 gigahertz upper frequency capacity, the coaxial cable has a 50 ohms RF impedance and a 960 MHz1 kW average power capability. While compatible with an automated prep tool, the product is sold per foot of length and available for bulk purchase. The Andrew AL4RPV aluminum coaxial cable has an off-white jacket color, an aluminum outer conductor and a copper-clad aluminum conductor inner lining. Featuring an air dielectric, the product is designed to be used with L4Txx-PSA style connectors.
Premium quality Plenum Rated Air Dielectric Coaxial Cable has corrugated aluminum. It is 1/2" thick with an off white PVDF jacket. This is 50 Ohm impedance coax cable with aluminum outside conductor and a copper-clad aluminum-inner conductor. Its maximum frequency capacity is 6.0 GHz. This transmission line uses type N-male connector for 1/2" coax cables. No automated prep tool available for this air dielectric cable. This is a SignalBooster.com premium quality cable part number AL4RPV-50-500. It boasts least attenuation and highest stability backed by 10 years of manufacturer warranty of CommScope.
Construction Materials:
Jacket Material | PVC |
---|---|
Dielectric Material | PE spline |
Flexibility | Standard |
Inner Conductor Material | Copper-clad aluminum wire |
Jacket Color | Off-white |
Outer Conductor Material | Corrugated aluminum |
Dimensions:
Nominal Size | 1/2 inch |
---|---|
Cable Weight | 0.14 lb/ft |
Diameter Over Jacket | 0.620 inch |
Inner Conductor OD | 0.1800 inch |
Outer Conductor OD | 0.553 in. |
Electrical Specifications:
Cable Impedance | 50 ohm ±2 ohm |
---|---|
Capacitance | 23.0 pF/ft |
dc Resistance, Inner Conductor | 0.480 ohms/kft |
dc Resistance, Outer Conductor | 0.480 ohms/kft |
dc Test Voltage | 4000 V |
Inductance | 0.058 μH/ft |
Insulation Resistance | 100000 Mohms•km |
Jacket Spark Test Voltage (rms) | 5000 V |
Operating Frequency Band | 1 – 6000 MHz |
Peak Power | 40.0 kW |
Power Attenuation | 2.325 |
Pulse Reflection | 0.5% |
Velocity | 88% |
Environmental Specifications:
Installation Temperature | +23 °F to +140 °F |
---|---|
Operating Temperature | -4 °F to +185 °F |
Storage Temperature | -4 °F to +185 °F |
Mechanical Specifications:
Bending Moment | 6.8 N-m | 5.0 ft lb |
---|---|
Fire Retardancy Test Method | NFPA 262/ CATVP/ CMP |
Flat Plate Crush Strength | 80.0 lb/in. |
Minimum Bend Radius, Multiple Bends | 5.00 inches |
Minimum Bend Radius, Single Bend | 2.50 inches |
Number of Bends, minimum | 15 |
Tensile Strength | 175 lb |
Standard Conditions:
Attenuation, Ambient Temperature | 68 °F |
---|---|
Average Power, Ambient Temperature | 104 °F |
Average Power, Inner Conductor Temperature | 212 °F |
Return Loss/ VSWR:
Frequency Band / VSWR / Return Loss (dB) | 700–2200 MHz / 1.13 / 24.30 |
---|
Regulatory Compliance/ Certifications:
Agency: Classification | RoHS 2011/65/EU: Compliant |
---|---|
Agency: Classification | ISO 9001:2008: Designed, manufactured and/or distributed under this quality management system |
Agency: Classification | ETL Certification: ATVP/CMP |
Agency: Classification | c(ETL)us Certification: CATVP/CMP |
Average Power at Specific Frequencies:
Average Power @ 30 MHz | 6.33 kW |
---|---|
Average Power @ 50 MHz | 4.86 kW |
Average Power @ 450 MHz | 1.52 kW |
Average Power @ 800 MHz | 1.1 kW |
Average Power @ 894 MHz | 1.04 kW |
Average Power @ 960 MHz | 1 kW |
Attenuation per 100 ft. at Specific Frequencies:
Attenuation/100 ft @ 30 MHz | 0.367 dB |
---|---|
Attenuation/100 ft @ 50 MHz | 0.478 dB |
Attenuation/100 ft @ 150 MHz | 0.848 dB |
Attenuation/100 ft @ 450 MHz | 1.53 dB |
Attenuation/100 ft @ 824 MHz | 2.14 dB |
Attenuation/100 ft @ 894 MHz | 2.24 dB |
Attenuation/100 ft @ 960 MHz | 2.332 dB |
Attenuation/100 ft @ 1700 MHz | 3.24 dB |
Attenuation/100 ft @ 2.0 GHz | 3.564 dB |
Reviews
Questions & Answers
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.
Data Sheet / User Guide
Make An Offer
Warning
Note: For any signal booster to help, outside signal strength must be at least -110 dB or there must be a clear line of sight to a cell tower that is within twenty miles. Before ordering, please check outside signal level in decibels or ensure that you can make and hold a phone call at any good spot outside where you can mount an exterior antenna. Square footage stated in signal booster listings is based on good signal outside. If it is any weaker, the boosted sq. ft. area will be considerably lower, accordingly.
Kevin K. of Anderson, California gave the following review:
Website is easy to use with plain straight forward info but could have had more on testing signal strength to make sure you get a strong enough booster.
Therefore, please note that stated sq. ft. coverage is based on good signal outside. For best results: If outside signal is weak, we suggest choosing the next higher sq. ft. coverage kit. If outside signal is very weak, we suggest choosing the kit with even more higher sq. ft. range bracket. Basically, higher the sq. ft. bracket, the more powerful the signal amplifier with greater Gain as well as higher uplink and downlink output power.
If outside signal is too weak (weaker than -110 dB), submit request for cell coverage solution assessment. Upon receipt of questionnaire, we will perform residential or business site survey. This will help us determine the system that is needed to improve cell coverage. Then, we will create system design using that system such as femtocell, active or hybrid distributed antenna system (DAS), or other carrier feed signal enhancing method available that will work at your signal-challenged location. Finally, we will schedule for installation after equipment and installation service quote has been approved by you, or your company.
For non installation-included kits: Most home / office / building cell signal booster kits only include bracket to mount exterior antenna on outside wall, edge of roof, or existing pipe up to 2 inches in diameter. Mounting pole not included with most kits, unless stated specifically that it is included for free. Therefore, a mounting post must be purchased separately if you will require it to mount exterior antenna.
Related Products