Public Safety DAS BDA Signal Booster Battery Back-Up Power System
Public Safety DAS BDA Signal Booster Battery Back-Up Power System
Buy Now, Pay Later with No Interest if paid in full within 6-12 months. Choose Klarna payment option at the checkout for details of this, and other long-term low-interest financing options.
Free Lifetime Support. SKU / Model: PE-12V-120W-18AH
Highlights:
- NFPA Compliant with all required monitoring alarms.
- Battery Included.
- NEMA-4 Enclosure.
- Customization to meet local AHJ's requirements.
- Pre-wired internal and external, with water-proof feed throughs for easy on-site connections.
1(855)846-2654
Need installation quote, or help with designing a custom solution? Submit a request for quote.
- Description
- Reviews
- Questions & Answers
- Data Sheet / User Guide
- Make An Offer
- Warning
Description
Product Description
Public safety DAS and BDA signal booster battery back-up power system is NFPA compliant. Every public safety distributed antenna system (DAS) and bi-directional amplifier (BDA) signal enhancing system for in-building coverage requires this because an integral part of an in-building solution for emergency response radio coverage is the backup power system. This battery backup system is perfectly suited for SureCall Guardian 3 QR Bi-Directional Signal Amplifier System and others like it. See "Data Sheet" tab above for the list of model numbers available, and their specifications.
NFPA codes relating to the autonomous operation and monitoring of the BDA power is quite stringent. Therefore, its back up power enclosure was engineered to meet every aspect of NFPA 72 and provide integrators configuration flexibility and rapid delivery directly to site, batteries included. Satisfies all local state, county, city fire department's fire marshal's fire codes. Manufacturer Part # PE-110V-100W-100AH/24V. UPC: 729198626778.
Features:
- NFPA Compliant with all required monitoring alarms.
- Batteries included.
- NEMA-4 Enclosure.
- Prewired internal & external, with waterproof feed thru's for easy on-site connections.
- Customization to meet local AHJ ‘s requirements.
Critical Specifications:
- Voltage: 110V AC.
- AC Output: 100 Watts.
- DC Output: 24V DC, 300 Watts.
- Battery Back-Up: 100 Amp-Hour.
Ideal Applications:
- Commercial Buildings, Convention Centers.
- Industrial Factories and Manufacturing Plants.
- Government Establishments and Facilities.
- Hospitality Industry Hotels and Motels.
- Education - Schools, Colleges, Universities.
Alternate Part Numbers:
- PE110V100W100AH/2
- PE110V100W100AH/24V
- PE-110V-100W-100AH/2
- PE110V100W100AH/24V
- PE-110-100W-100AH/24V
- PE110100W100AH/24V
110 Volt NFPA 1221 Integrated Power System Details:
- PE-110V-100W-100AH-24V Instruction Manual.
- BDS-DIN-24-10 Manual.
- 110V AC/24V DC with Inverter Wiring Diagram.
- PE Mounting Layout.
WE INSTALL. Please contact us for a quote if you require professional installation and assistance with consent and approval process for Public Safety Distributed Antenna System (active DAS) or Public Safety Bi-Directional Amplifier System (passive BDA).
General Specs.
Hazmat Form Req. | U |
---|---|
Hazmat Description | Sealed, Non-Spillable Lead Acid Battery |
AC Input Voltage Range | 90-264 V |
DC Input Voltage | 0 V |
DC Input Voltage | 0 V |
AC Input Voltage | 110 V |
HAZMAT UN Number | UN2800 |
Crowbar Protection | Yes |
Power Interface | Terminal Block |
Operating Temperature Range | 0-50 deg C |
Enclosure Type | Aluminum |
Enclosure Rating | NEMA 4X |
Enclosure Mount Type | Pole / Wall |
Power Enclosure Series Specifications for NFPA 1221 Standards.
Model | PE-110-100W-100AH/24V |
---|---|
AC Voltage | 110V AC |
DC UPS Power Watts | 96 Watts |
Battery A/H Capacity | 100 |
Enclosure Case Size | A |
System Weight (Lbs.) | 191 |
Shipping Weight (Lbs.) | 231 |
PE Series Battery Specifications for NFPA 1221 Standards.
Model | PE-110-100W-100AH/24V |
---|---|
Battery | PYL12V100FS |
Quantity | 2 |
Electrolyte Content Pounds | 91.3 |
Electrolyte Content Gallons | 6.3 |
PE Series Battery Run Time Specifications for NFPA 1221 Standards.
Model | PE-110-100W-100AH/24V |
---|---|
Amp-Hours | 100 |
Max Continuous Load 24 Hour Rating* | 96W |
Downloadable Content | Data Sheet |
*Based on 100% duty cycle. Back-up time increase if intermittent duty cycle loads applied.
From the manufacturer:
NewMar manufacturer specifications are subject to change for PE-110VAC-100W-100AH/24V Kit with Power Enclosure, 110V AC, 100 Watts, 100 Amp-Hour, 24V DC Power System. Manufacturers Warranty: 2 years.
Enclosure sizes:
Enclosure A: NEMA-4, UL listed (E465553), welded aluminum with IP 65 battery vent and locking door, 4 each 1/2 inch knock-outs for cable entry on sides and bottom (16 total), IP-68 cable entries. Red powder coat wall mount.
Size: Height = 26 inches x Width = 22 inches x Depth = 10 inches.
Enclosure B: NEMA-4, welded aluminum with IP 65 vent, pad lockable door handle, 8 each 1/2 inch knock-outs for cable entry (4 ea. on bottom left and right), IP-68 cable entries. Red powder coat wall mount.
Size: Height = 19 inches x Width = 24 inches x Depth = 20 inches.
Specifications per NFPA 1221 Standards.
An integral part of an in-building solution for emergency response radio coverage is the backup power system. NFPA codes relating to the autonomous operation and monitoring of the BDA power is quite stringent. These back up power enclosures were engineered to meet every aspect of NFPA 1221 and provide integrators configuration flexibility and rapid delivery directly to site, batteries included.
Model | Listed to UL Standard | DC Voltage | Max. BDA Load Amps | Battery A/H Capacity** | Enclosure Case Size | System Weight (Lbs.) | Shipping Weight (Lbs.) |
---|---|---|---|---|---|---|---|
PE-12V-120W-18AH | N/A | 12V | 1.5A | 18 | A | 49 | 89 |
PE-12V-120-18AH-UL2524 | 2524 & 924 | 12V | 1.2A | 18 | A | 49 | 89 |
PE-12V-120W-55AH | N/A | 12V | 4.6A | 55 | A | 75 | 115 |
PE-12V-120-55AH-UL2524 | 2524 & 924 | 12V | 3.8A | 55 | A | 75 | 115 |
PE-12V-120W-100AH | N/A | 12V | 8.5A | 100 | A | 111 | 151 |
PE-12V-120-100AH-UL2524 | 2524 & 924 | 12V | 5A | 100 | A | 111 | 151 |
PE-24V-240W-18AH | N/A | 24V | 1.5A | 18 | A | 63 | 103 |
PE-24V-240-18AH-UL2524 | 2524 & 924 | 24V | 1.2A | 18 | A | 63 | 103 |
PE-24V-240W-55AH | N/A | 24V | 4.6A | 55 | A | 114 | 154 |
PE-24V-240-55AH-UL2524 | 2524 & 924 | 24V | 3.8A | 55 | A | 114 | 154 |
PE-24V-240W-100AH | N/A | 24V | 8.5A | 100 | A | 186 | 226 |
PE-24V-240-100AH-UL2524 | 2524 & 924 | 24V | 5A | 100 | A | 186 | 226 |
PE-48V-265W-18AH | N/A | 48V | 5.5A | 18 | C | 81 | 116 |
PE-48V-265W-36AH | N/A | 48V | 5.5A | 36 | C | 138 | 173 |
PE-48V-480W-18AH | N/A | 48V | 1.5A | 18 | A | 90 | 130 |
PE-48V-480-18AH-UL2524 | 2524 & 924 | 48V | 1.2A | 18 | A | 90 | 130 |
PE-48V-480W-55AH | N/A | 48V | 4.6A | 55 | A | 190 | 230 |
PE-48V-480-55AH-UL2524 | 2524 & 924 | 48V | 4A | 55 | A | 190 | 230 |
PE-48V-480W-82AH | No | 48V | 6.6A | 82 | B | 283 | 323 |
PE-48V-480-82AH-UL2524 | 2524 & 924 | 48V | 6.6A | 82 | B | 283 | 323 |
PE-48V-480W-100AH | N/A | 48V | 8.5A | 100 | B | 371 | 411 |
PE-48V-480-100AH-UL 2524 | 2524 & 924 | 48V | 8.5A | 100 | B | 371 | 411 |
PE-110V-100W-100AH/24V * | N/A | 110V AC | 1.5A | 100 | A | 191 | 231 |
PE-110V-165-100AH/24V-UL2524 * | 2524 & 924 | 110V AC | 1.4A | 100 | A | 191 | 231 |
Reviews
Questions & Answers
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.
Data Sheet / User Guide
Make An Offer
Warning
Note: For any signal booster to help, outside signal strength must be at least -110 dB or there must be a clear line of sight to a cell tower that is within twenty miles. Before ordering, please check outside signal level in decibels or ensure that you can make and hold a phone call at any good spot outside where you can mount an exterior antenna. Square footage stated in signal booster listings is based on good signal outside. If it is any weaker, the boosted sq. ft. area will be considerably lower, accordingly.
Kevin K. of Anderson, California gave the following review:
Website is easy to use with plain straight forward info but could have had more on testing signal strength to make sure you get a strong enough booster.
Therefore, please note that stated sq. ft. coverage is based on good signal outside. For best results: If outside signal is weak, we suggest choosing the next higher sq. ft. coverage kit. If outside signal is very weak, we suggest choosing the kit with even more higher sq. ft. range bracket. Basically, higher the sq. ft. bracket, the more powerful the signal amplifier with greater Gain as well as higher uplink and downlink output power.
If outside signal is too weak (weaker than -110 dB), submit request for cell coverage solution assessment. Upon receipt of questionnaire, we will perform residential or business site survey. This will help us determine the system that is needed to improve cell coverage. Then, we will create system design using that system such as femtocell, active or hybrid distributed antenna system (DAS), or other carrier feed signal enhancing method available that will work at your signal-challenged location. Finally, we will schedule for installation after equipment and installation service quote has been approved by you, or your company.
For non installation-included kits: Most home / office / building cell signal booster kits only include bracket to mount exterior antenna on outside wall, edge of roof, or existing pipe up to 2 inches in diameter. Mounting pole not included with most kits, unless stated specifically that it is included for free. Therefore, a mounting post must be purchased separately if you will require it to mount exterior antenna.